Indicator for 6 thermocouples with 12 alarm outputs
The D1-60TC is a module suited for DIN rail mounting that can be linked to a local operator panel (F1-10); it provides 6 input channels for reading of temperature through thermocouples, with automatic cold junction compensation; the double ramp conversion circuit ensures a reliable reading with a 16 bit resolution and a 0.05 % full scale accuracy; the module does not require calibration and mantains its characteristics of accuracy; analog inputs, power section and communication interface are optically isolated; 12 optically isolated digital outputs can be configured as alarm units with/without hysteresis; an internal watch-dog circuit ensures a non-stop operation; a RS422/485 serial interface with Modbus (ASCII or RTU) protocol is also available. You can connect the F1-10 panel to interface the device , and /or (if you have loaded the " Device Log " program ) you can use the RS485/422 serial Modbus interface that gives you a complete control of all the implemented functions. D1-60TC Manual

The temperature indicator with alarm outputs The optional frontal panel for supervising and programming
Power supply From 9 to 36 Vdc, 100 mA @ 24 Vdc (without F1-10), 170 mA (with)
Power supply protections Against surge, voltage peaks and polarity inversion
Operating environment Temperature: from 0 to 70 °C, relative humidity: from 25 to 85 % (non condensing)
Operating atmosphere Without corrosive gas
Storage temperature From -20 to 80 °C (without ice)
Electromagnetic compatibility : Radio frequency emissions: EN55011 Group 1 Class A
Conducted emissions: EN55011 Group 1 Class A
Radio frequency immunity: ENV50140 10 V/m AM from 80 to 1000 MHz
Conducted immunity: ENV50141 10V/m AM from 0.15 to 80 MHz
IP grade Connectors: IP20, enclosure: IP20
Insulation Between analog inputs and digital inputs/outputs: 500 V
Between analog inputs and power supply section: 500 V
Between analog inputs and 485/422 section: 1000 V
Between digital inputs/outputs and 485/422 section: 1500 V
Between power supply and 485/422 sections: 1500 V
Signalling leds Power on, self-test, digital inputs and outputs status, serial tx, serial rx
Mounting mode DIN EN50022 rail
Dimensions 175L x 120H x 65P mm
Weight 450 g
Ordering code : D1-60TC
ANALOG INPUTS SPECIFICATIONS
Sensor type 6 thermocouple sensors (type J, K, N, R, S, T) or voltage sensors (from 0 to 50 mV)
Analog/digital conversion Double ramp, 16 bit resolution
Voltage allowed From -10 mV to 80 mV
Overall accuracy ±0.05 % full scale
Acquisition rate 1 s (all the six channels)
Full scale temperature range From -100 to 1760 °C
Cold junction compensation From 0 to 70 °C
DIGITAL INPUTS SPECIFICATIONS
Input type 2 inputs, optoisolated, common positive (power supply voltage)
Voltage levels Active state: from 15 to 36 V, non active state: from 0 to 4 V
Current sinked 10 mA @ 24 V
Detectable pulse duration Not less than 500 ms
DIGITAL OUTPUTS SPECIFICATIONS
Output type 12 outputs PNP transistor open collector, pull-down resistor: 22 k to ground
Output voltage when active The voltage supply
Maximum load current 100 mA each output
Protections Suppression diode, overvoltages and short circuit
COMMUNICATION INTERFACE SPECIFICATIONS
Communication interface EIA RS485 or RS422 (selectable by dip-switches)
Communication speed 9600 or 19200 baud (selectable by dip-switches)
Communication protocol Modbus ASCII or Modbus RTU (selectable by dip-switches)
Device address From 1 to 63 (selectable by dip-switches)
485/422 lines protections Against surge, short circuits and voltage peaks
Pull-up and pull-down resistors 10 k
FUNCTIONAL SPECIFICATIONS
Watch-dog Hardware . No stop Module.
Read software filter Moving average, 8 samples depth (individually selectable for each channel)
Input linearization For 0-50 mV voltage input type, individually configurable for each channel
Intercepting mode : Levels mode or hysteresis mode with programmable levels
Input / output links Individually configurable
Retaining alarms Individually selectable
Retaining alarms reset mode : All alarms reset by using one of the digital inputs, individually reset by using F1-10 operator panel
Outputs : With activation and deactivation time filters